Model | DS-C9124V-24PETK9 |
Protocols | • Fibre Channel standards • FC-PI-6 (INCITS 512-2015) • FC-PI-7 (INCITS 543-2019) • FC-FS-4 (INCITS 488-2016) • FC-FS-5 (INCITS 545-2019) • FC-GS-7 (INCITS 510-2017) • FC-GS-8 (INCITS 548-2020) • FC-LS-3 (INCITS 487-2018) • FC-LS-4 (INCITS 553-2020) • FC-SW-6 (INCITS 511-2016) • FC-SW-7 (INCITS 547-2020) • NVMe/FC (INCITS 540-2018) • NVMe/FC-2 (INCITS 556-2020) • FC-PH, Revision 4.3 (ANSI INCITS 230-1994) • FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996) • FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999) • FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997) • FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998) • FC-PI, Revision 13 (ANSI INCITS 352-2002) • FC-PI-2, Revision 10 (ANSI INCITS 404-2006) • FC-PI-3, Revision 4 (ANSI INCITS 460-2011) • FC-PI-4, Revision 8 (ANSI INCITS 450-2008) • FC-PI-5, Revision 6 (ANSI INCITS 479-2011) • FC-FS, Revision 1.9 (ANSI INCITS 373-2003) • FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007) • FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007) • FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011) • FC-FS-4 • F-LS, Revision 1.62 (ANSI INCITS 433-2007) • FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011) • FC-LS-3, Includes revision 3.53 • FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001) • FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004) • FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006) • FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010) • FC-SW-6 • FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001) • FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004) • FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007) • FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010) • FC-GS-7, Includes revision 10.8 • FCP, Revision 12 (ANSI INCITS 269-1996) • FCP-2, Revision 8 (ANSI INCITS 350-2003) • FCP-3, Revision 4 (ANSI INCITS 416-2006) • FCP-4, Revision 2b (ANSI INCITS 481-2011) • FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001) • FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003) • FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007) • FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011) • FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014) • FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003) • FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006) • FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008) • FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010) • FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014) • FC-VI, Revision 1.84 (ANSI INCITS 357-2002) • FC-SP, Revision 1.8 (ANSI INCITS 426-2007) • FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012) • FAIS, Revision 1.03 (ANSI INCITS 432-2007) • FAIS-2, Revision 2.23 (ANSI INCITS 449-2008) • FC-IFR, Revision 1.06 (ANSI INCITS 475-2011) • FC-FLA, Revision 2.7 (INCITS TR-20-1998) • FC-PLDA, Revision 2.1 (INCITS TR-19-1998) • FC-Tape, Revision 1.17 (INCITS TR-24-1999) • FC-MI, Revision 1.92 (INCITS TR-30-2002) • FC-MI-2, Revision 2.6 (INCITS TR-39-2005) • FC-MI-3, Revision 1.03 (INCITS TR-48-2012) • FC-DA, Revision 3.1 (INCITS TR-36-2004) • FC-DA-2, Revision 1.06 (INCITS TR-49-2012) • FC-MSQS, Revision 3.2 (INCITS TR-46-2011) • Fibre Channel classes of service: Class 2, Class 3, and Class F • Fibre Channel standard port types: E and F • Fibre Channel enhanced port types: SD, ST, and TE • NVMe/FC • In-band management using IP over Fibre Channel (RFC 2625) • IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338) • Extensive IETF-standards based TCP/IP, SNMPv3, and remote monitoring (RMON) MIBs |
Fibre Channel ports | • Fixed-switch form factor with 24 SFP+ ports base |
Security | • VSAN fabric isolation • Intelligent packet inspection at port level • Hardware zoning by Access Control Lists (ACLs) • Fibre Channel Security Protocol (FC-SP) switch-to-switch authentication • FC-SP host-to-switch authentication • Role-Based Access Control (RBAC) using RADIUS, TACACS+, or Lightweight Directory Access Protocol (LDAP) authentication, authorization, and accounting (AAA) functions • Secure FTP (SFTP) • Secure Shell Protocol Version 2 (SSHv2) • Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES) • Control-plane security • Cisco TrustSec ® payload encryption • Secure Boot and Anti-counterfeit technology |
Performance | • Port speed: 8-, 16-, 32 and 64-Gbps autosensing with 64 Gbps of dedicated bandwidth per port • Aggregate bandwidth of 1.5-Tbps end-to-end full duplex • Buffer credits: Up to 24,000 for a group of 24 ports, with a default of 1000 buffer credits per port and a maximum of 16,000 buffer credits for a single port in the group • Port groups: 1 port group of 24 ports • Port channel: Up to 24 load-balanced physical links grouped in one port channel |
Diagnostics | • Power-On-Self-Test (POST) diagnostics • Online Health Management System (OHMS) diagnostics • Internal loopbacks • SPAN • Fibre Channel traceroute • Fibre Channel ping • Fibre Channel debug • Cisco Fabric Analyzer • Syslog • Port-level statistics • Link diagnostics (E-port and F-port links) • Read Diagnostic Parameter |
Serviceability | • Configuration file management • Call Home • Port beaconing • Link cable beacon • System LEDs • SNMP traps for alerts |
Reliability and availability | • Cisco In-Service Software Upgrade (ISSU) • Hot-swappable, dual redundant power supplies • Hot-swappable fan tray with switch integrated temperature and power management • Hot-swappable SFP+ optics • Stateful process restart • Any port configuration for port channels • Fabric-based multipathing • Per-VSAN fabric services • Port tracking • FEC with HBA ports • Buffer-to-buffer state change notification with HBA ports |
Network management | • Management access through the following out-of-band Ethernet ports ◦ mgmt0: 10/100/1000BASE-T port • RS-232 serial console port • USB power-on auto-provision port • Access protocols • Command-Line Interface (CLI) using the console and Ethernet port • SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access • Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S) • NX-API for HTTP/HTTPS full programmability • Distributed device alias service • Network security • Per-VSAN RBAC using LDAP, RADIUS, and TACACS+-based AAA functions • Simple File Transfer Protocol (SFTP) • SSHv2 implementing AES • SNMPv3 implementing AES |
Programming interfaces | • Scriptable CLI • Cisco DCNM/NDFC web services API • NX-API HTTP/HTTPS interfaces • Onboard Python interpreter • Cisco Embedded Event Manager (EEM) • Cisco NX-OS Software scheduler |
Physical dimensions (H x W x D) and weight | • 1 Rack Unit (1RU) 4.37 x 43.94 x 45.72 cm excluding Power Supply Unit (PSU) and fan-tray handles • 8.5 kg |
Power | • 80 Plus Platinum certified power supplies • Power supply options ◦ 500W AC in base model, port-side exhaust variant (2 per switch) ◦ 500W AC in base model, port-side intake variant (2 per switch) ◦ 1200W AC/ HVAC/ HVDC in base model, Bidirectional airflow (2 per switch) • Power cord ◦ Notched C15 socket connector connecting to C16 plug on the power supply receptacle for 500W Power Supply ◦ Standard CAB-HVAC-C14-2M IEC C14 to Saf-d-grid connector on the power supply receptacle for 1200W Power Supply ◦ Check Ordering Information table in this document for power cords specific to regions • 500W PSU AC input: 100 to 240 VAC (10% range) • 1200W PSU AC input: 90V to 305V • 1200W PSU DC input: 192V to 400V • Frequency: 50 to 60 Hz (nominal) • Typical power consumption ◦ 94W for 24-Port switch in idle status with no optics modules ◦ 113W for 24-Port switch with 8 64G SW optics modules under 50% line rate ◦ 146W for 24-Port switch with 24 64G SW optics modules under 50% line rate • Airflow ◦ Back to front (toward ports) using port-side exhaust fans ◦ Front to back (inward from ports) using port-side intake fans ◦ 50 Cubic Feet per Minute (CFM) through system fan assembly at 25°C • 100 CFM maximum |
Temperature range | • Temperature, ambient operating: ◦ 0 to 40°C with port-side exhaust and intake airflow variants • Temperature, ambient nonoperating and storage: –40° to 70°C • Relative humidity, ambient (noncondensing) operating: 10% to 90% • Relative humidity, ambient (noncondensing) nonoperating and storage: 10% to 95% • Altitude, operating: –60 to 2000m |
Approvals and compliance | • Safety compliance • CE Marking • UL 60950 • CAN/CSA-C22.2 No. 60950 • EN 60950 • IEC 60950 • TS 001 • AS/NZS 3260 • IEC60825 • EN60825 • 21 CFR 1040 • EMC compliance • FCC Part 15 (CFR 47) Class A • ICES-003 Class A • EN 55022 Class A • CISPR 22 Class A • AS/NZS 3548 Class A • VCCI Class A • EN 55024 • EN 50082-1 • EN 61000-6-1 • EN 61000-3-2 • EN 61000-3-3 |
Fabric services | • Name server • Registered State Change Notification (RSCN) • Login services • Fabric Configuration Server (FCS) • Broadcast • In-order delivery |
Advanced functions | • VSAN • IVR • Port Channel with multipath load balancing • Flow- and zone-based QoS |